Energy Efficient Works - Technical Specifications and Considerations
All works must be undertaken by an SEAI registered Contractor in accordance with the technical requirements set out in the Contractor Code of Practice and Technical Specification. The table below sets out the summary performance requirements. An optimum solution for the entire home has to be implemented.
Waterford Insulation SEAI Registered Contractor Number - 10284
| Measure | Summary Requirement | |
|---|---|---|
| Insulation | Attic Insulation | Ceiling Level: Target U-Value ≤ 0.16 W/m2K Rafter Level: Target U-Value ≤ 0.20 W/m2K |
| Wall Insulation - Cavity | NSAI Agrément certified system Target U-Value ≤ 0.27 W/m2K | |
| Wall Insulation - External | NSAI Agrément certified system Target U-Value ≤ 0.27 W/m2K | |
| Wall Insulation - Internal Dry Lining | Target U-Value ≤ 0.27 W/m2K | |
| Heating System | High Efficiency Oil / Gas Boiler with Controls upgrade. |
Upgrade comprising
|
| Heating Controls Upgrade only |
Upgrade Comprising
| |
| Solar Heating | Product (panel) must be on SEAI registered product list and supplying > 10 kWh/ m2Yr | |
| Building Energy Rating (BER) | Use registered BER assessor and BER published on National Administration System | |